2-Bin/Shift Tray
<Shift Tray>
1. Rear Cover: Loosen four screws and slide the cover toward to the rear.
2. Top Cover: Remove the Front and Rear Covers and lift the cover upward.
3. Front Cover: Remove the Lower Front Cover, loosen four screws, and slide the cover to the front.
4. Lower Front Cover: Unlock the tabs and slide the cover to the front.
6.6.2.1.2 Cleaning of the Paper Exit Roller

6.6.2.2 Adjustment

Path Switching Solenoid Stroke Adjustment
Wipe the surface of the Paper Exit Roller clean of dirt
with a cloth dampened with alcohol.
1. Remove the Main Board.
2. Loosen the two screws that secure the solenoid and adjust its position so
that dimension A measures 5.2 to 4.7 mm (Job Tray) or 4.4 to 3.9 mm (Shift
Tray).
6-69