5.2.39 Exposure lamp

1. Remove the Right and left cover. (See 5.2.26.)
2. Remove Size cover H. (See 5.2.33.)
3. Remove FBS glass. (See 5.2.33.)
4. Remove Panel assembly. (See 5.2.24.)
5. Remove the blind sheet and then remove a screw on the exposure lamp bracket.
6. Remove the connector cover, then disconnect the connector.
7. Remove the exposure lamp.