3.7 Unique Switch Adjustment

3.7.1 Setting the Unique Switches
These switches are used to program internal machine parameters. The primary back up battery maintains
these settings if power is lost.
1. From standby, press MENU, *, 4.
2. Select the desired unique switch by cursor key or by pressing a one-touch key plus a number on the
keypad. For example, to access unique switch B:1, press one-touch "B" plus the number "1" on the
numeric keypad.
3. Press [Enter].
4. To navigate through the unique switch settings:
Press
or
Press 0 or 1 on the numeric keypad to change the bit value.
Press [Enter] to save the setting of the displayed unique switch and advance to the next unique
switch.
Press [Cancel] not to save the setting of the displayed unique switch.
5. If you want to set other unique switches, repeat step 3-5. Otherwise, proceed to step 6.
6. Press RESET to return the machine to standby.
3.7.2 Clearing the Unique Switches
Resets the unique switches to factory defaults.
1. From standby, press MENU, *, 4, [Clear].
3. Press [Enter]. The unique switches will reset to factory defaults.
Note: To finish the operation without clearing the unique switches, press [Cancel].