Section3 Software Adjustment; Field Service Program Modes - Muratec MFX-2500 Field Engineering Manual

Hide thumbs Also See for MFX-2500:
Table of Contents

Advertisement

Section3
Software adjustment

3.1 Field Service Program Modes

The machine feature maintenance modes for machine adjustment. Each mode is listed below along with
the command used to activate the mode and a brief functional description.
Set or Clear Machine Parameters..........................................................................................MENU, *, 0
Used to set or clear machine parameters.
Set or Clear Memory Switches ..............................................................................................MENU, *, 1
Used to set or clear memory switches.
Clear Programmed Data / User Settings...............................................................................MENU, *, 2
Erases user-programmed information (date, time, TTI, autodialer, etc.) and any documents
stored in memory.
All RAM Clear ..........................................................................................................................MENU, *, 3
Erases same information as "Clear Programmed Data / User Settings" function along with
resetting all of the machine parameters, memory switches and unique switches to factory
defaults.
Set or Clear Unique Switches................................................................................................MENU, *, 4
Used to set or clear Unique switches.
Print Program Mode List ........................................................................................................MENU, *, 8
Prints a list of the machine's programming modes.
Test Modes ..............................................................................................................................MENU, *, 9
Allows the technician to perform a series of diagnostic tests.
Print Machine Parameters, Memory Switches and
Unique Switches List............................................................................................................. MENU, *, A
Prints a list of the machine switch settings showing the default settings and current settings.
Factory Functions.................................................................................................................. MENU, *, B
Allows the technician to perform a series of diagnostic tests.
Telephone Circuit Test Modes ............................................................................................. MENU, *, C
Allows the technician to perform a series of diagnostic tests.
Mirror Carriage Transfer Mode ............................................................................................. MENU, *, E
Perform it before installing the machine.
Set and print the consumable order sheet.......................................................................... MENU, *, F
Used to set and print the consumable order sheet.
DRAM Clear ............................................................................................................................MENU, *, G
Used to clear a DRAM.
Clear Life Monitor .................................................................................................................. MENU, *, H
Used to clear a Life monitor keeps a count of the pages scanned, etc.
Set Service Code ....................................................................................................................MENU, *, J
Used to protect to clear a Life monitor.
Clear the consumable order sheet....................................................................................... MENU, *, L
Used to clear the consumable order sheet.
Reset Printer trouble .............................................................................................................MENU, *, M
Used to reset the printer trouble indication.