5.3.2 Printer registration (side)

A
Adjust so that width A on the test pattern D output falls within the following range.
Specification
10 ± 2.0 (mm)
Adjustment procedure
1. Load the A3-sized paper to the cassette.
2. Use the Unique Switch F:2 to adjust the printing margin to 0 mm. (Press MENU, [, 4. For detail, see
page 3-114.)
3. Produce a test pattern D with the A3-sized paper.
(Press MENU, [, 9, Test Pattern Print. For detail, see page 3-123.)
4. Check to see if width A on the test pattern D meets the specifications.
If width A falls outside the specified range, perform following steps to make the adjustment.
5. Entry the Machine Parameter mode. (Press MENU, [, 0. For detail, see page 3-2.)
6. Adjust the setting of Machine Parameter K to meet the specification.
If the width A is shorter than specification, increase value.
If the width A is longer than specification, decrease value.
Important: When you change the setting of Machine Parameter K, you must set the same value to
Machine Parameter M.
Ex.) If you set the "00000010" to the Machine Parameter K:5, you must set the "00000010" to
the Machine Parameter M:5, too.
When you change the setting of Machine Parameter L, you must set the same value to
Machine Parameter N.
Important: After adjustment, you must re-enter the setting of Unique Switch F:2, you changed in step 2.
A
Adjustment Tool
Machine parameter K
Machine parameter L
5-82
Test pattern D
Setting Range
– 12.8 to 12.7 (mm)
(0.1 mm step)