5.2.21 Lock lever assembly

1. Remove the platen cover assembly. (See 5.2.17.)
2. Remove the Tx side cover. (See 5.2.10.)
3. Remove the document mount assembly (See 5.2.18.)
4. Remove two screws and Stay C.
Stay C
5. Remove spring and E-ring, then remove the Spring attachment.
Spring attachment