5.3.11.2 When the copy using the FBS is deformation as shown below, adjust the Mirror
carriage position.

Adjustment procedure

1. Load the A3-sized paper to the cassette.
2. Use the Unique Switch F:2 to adjust the printing margin to 0 mm. (Press MENU, [, 4. For detail, see
page 3-114.)
Important: After adjustment, you must re-enter the setting of Unique Switch F:2.
3. Place the Muratec Test Chart No. 99-1 on the FBS.
4. Make a copy of it on the A3-sized paper with 100 % magnification.
5. Measure the width of C and D on the copy to find the difference.
6. Subtract D from C.
If the difference falls outside the specified range, perform
the following steps to make the adjustment.
Specification: The difference of C and D should be within
± 1.5 mm.
If the C > D, move the front side of Mirror carriage B to the
rightward.
If the C < D, move the front side of Mirror carriage B to the
leftward.
Ex) If the difference is –2mm, move the front side of Mirror
carriage B 2mm to the leftward.
To move the front side of the mirror carriage:
Ex.) If measured vertical length C is 10 mm, and D is 6 mm.
Subtract D from C. (10-6= 4 mm)
1. Loosen a front side retainer screw of the Mirror carriage B.
2. Move the front side of the Mirror carriage B 4 mm to the
rightward.
3. Secure the Mirror carriage B.