5.2.60 Master board (PWB-A)
1. Remove the upper cover. (See 5.2.54.)
2. Remove the shield box. (See 5.2.55.)
3. Remove the two screws and MFB box.
4. Disconnect the all connectors and remove four screws, then remove the master board.
PWB-A
Remounting The EEPROM (IC3A)
Notes:
If the Imaging Cartridge is not to be replaced after the Master Board has been replaced with a new one,
be sure to remount the EEPROM (IC3A) from the old to new Master Board.
If the Master Board has been replaced with a new one and the EEPROM (IC3A) has not been
remounted, be sure to replace the Imaging Cartridge with a new one. Because the EEPROM contains
no data in this case, make settings and readjustments as necessary.
1. Remove the Master Board (PWB-A).
2. Demount the EEPROM (IC3A) from the new Master Board.
3. Demount the EEPROM (IC3A) from the old Master Board and remount it onto the new
New Master board
MFB box
New EPROM
Old Master board
5-71