3.2 Machine Parameter Adjustment

3.2.1 Setting the Machine Parameters

These switches are used to program internal machine parameters. The primary back up battery maintains
these settings if power is lost.
1. From standby, press Program key, *, 0.
Set Parameters
2. Press ENTER.
A0:
3. Select the desired parameter by pressing a one-touch key plus a number on the keypad. For example, to
access parameter B:1, press one-touch "B" plus the number "1" on the numeric keypad.
B1:
4. Press ENTER.
Set Parameters
B1
Bit No.
(The bits are numbered 7 through 0 --- bit 7 is left most.)
5. To navigate through the machine parameter settings:
Press
key to move the cursor to the left.
Press
to move the cursor to the right.
Press the 0 or 1 on the numeric keypad to change the bit value.
Press ENTER to save the setting of the displayed parameter and advance to the next parameter.
(Continue pressing ENTER until the desired parameter is shown in the display. Be sure to press
ENTER after each parameter is programmed to save the new setting.)
Press STOP to return the unit to standby.
Note: You can confirm the initial setting of each Machine parameter by the Machine Parameters List.
The Machine Parameters List will be printed by pressing Program key, *, A(01).

3.2.2 Clearing the Machine Parameters

Resets the machine parameters to factory defaults.
1. From standby, press Program key, *, 0,
Clear Parameters
2. Press ENTER.
Clear Parameters
Check
Enter/Cancel
3. Press ENTER. The machine parameters will reset to factory defaults.
Note: To finish the operation without clearing the parameters, press CANCEL.
/