LVD-SCSI-2 Port Configuration

0.5.2
The standard 68-pin LVD-SCSI-2 port connects the printer to the PosterShop RIP
platform via a standard 68-pin SCSI-2 data cable. The maximum length of this cable is 40
feet (12 meters).
Note: NEVER connect or disconnect SCSI cables with the printer or the host PC
powered ON.
1.
Navigate to:
MAIN MENU
CONFIGURE I/O
2.
Press the ACCEPT button. You then see:
CONFIGURE I/O
active: SCSI
If the current setting is parallel, you will see:
CONFIGURE I/O
active: parallel
Use the +/- buttons to select SCSI.
3.
Press ACCEPT. You then see:
SCSI PORT
SCSI address: (0 - 7)
This option specifies a SCSI address that identifies the printer to the host system.
Use the +/- buttons to select an address (0-6), as required.
Note: Never select address 7 as it is reserved for the SCSI controller card in the PC.
4.
Press ACCEPT. You then see:
SCSI Port
timeout XXX seconds
This option enables you to specify a time period in seconds (1-600) for the printer
to consider the job transfer complete, if an END OF PRINT command is not
received. The delay may need to be increased if the printer issues an error during
an image transfer. An error may be caused by large blank areas (no data) within the
image. Increase this value by at least 60 seconds and try again. Use the + button to
increment the timeout period.
The default setting is 60 seconds.