2. Scan two bar codes for the hex value "72" ("r," which represents the identifier for
the Aux Port). Scan the two digits from the "Programming Chart" in Appendix A.
3. Refer to the Hex to ASCII Conversion Chart to find the hex value that represents
the ASCII characters you wish to attach to the data. Use the "Programming Chart"
in Appendix A to scan the alphanumeric combination that represents the ASCII
characters.
4. To complete auxiliary prefix/suffix programming, scan either:
Save - This exits, saving the prefix/suffix selections you just assigned.
Discard - This exits without changing the prefix/suffix.
Other Programming Selections: Scanning the Default Prefix or Default Suffix bar code
sets the default prefix or suffix.
Scanning the Clear All Prefixes or Clear All Suffixes bar code deletes all prefix or
suffix selections.
If you want to turn off the prefix or suffix formatting for a period of time, scan Disable
Aux Prefix/Suffix. To turn back on, scan Enable Aux Prefix/Suffix.
Example 1: Add a Prefix
To add an HT (tab) prefix to incoming data.
1. Scan the Add Aux Prefix Prefix Selection bar code.
2. Scan 7 and 2.
3. An "HT" is equivalent to "09". Scan 0 and 9.
4. Scan Save.
Example 2: Add a Suffix
To add a CR (carriage return) suffix to incoming data.
1. Scan the Add Aux Suffix Suffix Selection bar code.
2. Scan 7 and 2.
3. A "CR" is equivalent to "0D". Scan 0 and D.
4. Scan Save.