lost power and running on battery back-up. If the power switch is left in the OFF (down)
position, the printer will not be protected and the battery will eventually discharge (see
Figure 1-3).
Power Switch

Figure 1-3 Battery Back-up Option

To verify the battery back-up unit is functional, perform the following steps:
1.
Power down the printer.
The battery back-up unit should power up the vacuum pump immediately upon
losing power. If the vacuum pump does not start running, check the position of the
battery back-up power switch. If the vacuum pump fails to run with the switch in
either position, the battery may be discharged and require charging.
2.
Power the printer back up.
The battery back-up unit should power down the vacuum pump immediately upon
the return of system power.
If the printer does not have the battery back-up vacuum control option and must be
powered off for more than two hours, you must call your Customer Service representative
to flush all ink from the system.
Though powered on, if the printer will not be printing for a period longer than two weeks,
contact your Customer Service representative to flush all ink from the system.