33234H
Symbol
Parameter
t
DOTCLK Period
CK
t
DOTCLK High time
CH
t
DOTCLK Low time
CL
DOTCLK long term output jitter
t
Skew between RED, GREEN, BLUE Output Valid
SKEW
Note 1. Measured as per VESA requirements. The jitter is observed at its worst case point on a scan line after HSYNC
triggers up to and including the next HSYNC trigger.
Note 2. HSYNC and VSYNC for CRT timing are generated from the same on-chip clock that is used to generate the RED,
GREEN, and BLUE signals.

Table 7-13. CRT Display Recommended Operating Conditions

Symbol
Parameter
V
Power Supply connected to
DAC
DAV
DD
R
Output Load RED, GREEN and
L
BLUE
I
Output Current RED, GREEN
OUT
and BLUE
R
Value of the full-scale adjust
SET
resistor connected to DRSET
VEXT
External voltage reference con-
REF
nected to the DVREF pin
Note 1. There is a 75 Ω resistor on the motherboard and a 75 Ω resistor in the CRT monitor to create the effective 37.5 Ω
typical resistance.
612

Table 7-12. CRT Interface Signals

Min
Typ
3.14
3.3
37.5
Note 1
1.2K
1.235
Min
Max
Unit
2.8
1.2
1.2
15%
t
CK
0
0.6
Max
Units
Comments
3.46
V
Ω
One each signal.
21
mA
One each signal.
Ω
This resistor should have a
1% tolerance.
V
AMD Geode™ LX Processors Data Book
Electrical Specifications
Comments
ns
350 MHz
ns
45% t
CK
ns
45% t
CK
Note 1
ns
Between any
two signals
Note 2