Table 5-3
Defined Tokens (continued)
Token
Read %S variables state—reads the values of all twenty %S variables (%S0~%S19) from the
specified file. The format expected is a one line, comma delimited, ASCII file where the first value is
%S0, the second is %S1, etc.
When the [( ) token is used with the ]( ) token, you can read, modify, and write (remember) %S
variables.
Note To avoid potential simultaneous access errors: within the same User ID, if you read with the [( )
token, write with the ]( ) token.
[( )
Syntax [(file)
where:
file
ASCII file with columns separated by commas (comma delimited). Valid 8x3 DOS file name.
Can be a variable.
Note Maximum of 1 custom-made file is taken as 4KB.
Write %S variables state—writes the values of all twenty %S variables (%S0~%S19) to the specified
file. Typically, you would use this with the [( ) token which reads the %S variables.
Note To avoid potential simultaneous access errors: within the same User ID, if you read with the [( )
token, write with the ]( ) token.
]( )
Syntax ](file)
where:
file
ASCII file with columns separated by commas (comma delimited). Valid 8x3 DOS file name.
Can be a variable.
Note Maximum of 1 custom-made file is taken as 4KB.
Change port volume—changes the volume of the current port to the specified level.
Notes
•
The voice processing system configuration
for all ports
•
For the user, the current port volume can be set through the Users Menu's
field and by the user with the Play Message Controls
^( )
Syntax (n)
where:
n
Volume of current port
(range: -2~4). -2 is the softest
0 is the initial volume
4 is the loudest.
Strata CIX40 Voice Processing Programming Manual
(Chapter 2 – Configure UADM2 Software
7/06
Description
gain_norm
parameter sets the starting volume
).
(Chapter 4 –
Token Programming
Defined Tokens
Message Volume
Menus).
19