Configure UADM2 Software
SMDI Integration
Table 2-3
SMDI Parameters
Parameter
smdi_base_port
smdi_port
smdi_pretimeout
smdi_type
2-22
Some SMDI installations use logical terminal numbers that do not begin with 1 (for
example, if it uses the extension or physical number to define the terminal). In these
situations, you must define the extension number where port 1 is connected. The
system assumes that the extension numbers are then connected in numerical order
to the remaining ports.
Example: 208 (extension number of port in Strata CIX40)
Default: 220
Logical serial port the GVPH uses for SMDI integration.
Default: 1
Note Fixed value, can not be changed.
Maximum number of seconds that an SMDI packet can precede the forwarded call.
Possible values: 5~50 (seconds)
Default: 50
Protocol the GVPH uses with data integration (outbound integration).
Default: 'smdi'
Note Default is fixed and cannot be changed.
Description