If the test switch did not execute correctly:






FIG. 30
DVI and SC fiber cable adapters

Instruction Manual – Enova DGX 8/16/32 Digital Media Switchers
Check the Power indicator on the front of the enclosure.
If it is not illuminated, check the power cords at the enclosure and at the power source.
Verify the status of the test switch. If status returns as routed correctly, the system established
a connection between the specified input and output connectors within the enclosure.
Control panel: use the Control Dial to scroll to Status. Press the Select Key. Press

Output Key 2 (turns white). If Input Key 1 turns white, the test switch is routed.
BCS commands: enter "SL0O2T". If "SL0O2T(1)" appears, the test switch is routed.

Check all link and signal connections on the rear of the enclosure(s) to make sure everything is
physically set up correctly.
If applicable – check connections on DGX Fiber Modules (also see "Troubleshooting" in the
Instruction Manual – DGX Transmitters & Receivers) and DXLink Modules/Wallplates (also
see "Troubleshooting" in the Instruction Manual – DXLink™ Twisted Pair Transmitters/
Receiver).
Check all power switches on the source and destination devices to make sure all are turned on.
Depending on the board type:
Isolate source/destination equipment and cable problems by patching around the router

using a cable adapter to check the overall signal path.
Check the SC fiber connectors to make sure they are fully inserted into the DGX Fiber

Module and that no dust or debris is on the exposed fiber ends of the cable or on the
module.
Check the documentation for the DGX Fiber Modules to be sure they are installed

correctly. Isolate source and destination devices using the modules to bypass the
enclosure to check the fiber cable and overall signal path.
Check the documentation for the DXLink™ Transmitters and Receivers to be sure they

are installed correctly. Isolate source and destination devices using the modules to bypass
the enclosure to check the twisted pair cable and overall signal path.
Attempt the switch again.
If the switch still does not work, contact technical support (see page 62).