AMX Enova DGX 8 Instruction Manual page 166

Dgx digital media switchers
Hide thumbs Also See for Enova DGX 8:
Table of Contents

Advertisement

Appendix A – DGX Configuration Software
Bypass Mode
Bypass mode allows the video signal to pass un-scaled through the system.
If an output connector fails to read the EDID from its attached destination device on power up (i.e., no
resolution data is available from the device), the output connector reverts to the Bypass mode until the video
cable is unplugged and then plugged in, at which time it will attempt to read the EDID again.
Note: When Bypass mode is selected, both interlaced and replicated format can be passed.
Manual (Override) Mode
When you select Manual in the Scaler Mode view, the program sets up the video scaler with the factory
default values (1280x1024 @ 60 Hz) for the selected outputs.
The Manual mode allows you to manually configure a specific or a custom scaled output resolution to send to
the display monitor(s). In this mode, the system ignores the EDID data being received from a display up to
1920x1200. When you select and set the Manual (override) scaler mode, select the Scaler Override tab to
configure the resolution (see page 161).
To change the Scaler Mode settings:
1.
Select the Scaler Mode tab.
FIG. 88
Scaler Mode view
2.
Select the desired output(s).*
3.
Click any or all of the following:


4.
Click the appropriate Set button(s) to persist the setting(s).
* When selecting multiple outputs: either select consecutive outputs by holding down the Shift key and
clicking the first and last output or select nonconsecutive outputs by holding down the Control key and
clicking on each output.
160
The desired Current and Default scaler modes (for explanations of the three modes, see the
previous page)
The Aspect Ratio of the display (for an explanation of the aspect ratio options, see the top of the