Enova Dgx - Netlinx And Control Specifications - AMX Enova DGX 8 Instruction Manual

Dgx digital media switchers
Hide thumbs Also See for Enova DGX 8:
Table of Contents

Advertisement

Enova DGX – NetLinx and Control Specifications
NetLinx and Control Specifications
Integrated Controller
LAN/ Ethernet Port
Processor
Memory
Program Port (USB)
Enclosure Control
Control Port (Serial)
Control Port (USB)
* Cascaded architecture actual throughput dependent on loading. Worst case per port throughput is 10 Mbps;
best case is 100 Mbps when used with a total of 32 DXLink TXs and 32 DXLink RXs for an Enova DGX 32,
16 DXLink TXs and 16 DXLink RXs for an Enova DGX 16, and 8 DXLink TXs and 8 DXLink RXs for an
Enova DGX 8.
For individual board information and specifications, see the specific board chapter in this manual.





AMX reserves the right to modify its products and their specifications without notice.
Instruction Manual – Enova DGX 8/16/32 Digital Media Switchers
NetLinx on-board Master is an NI-3100 Class Controller
• TCP/IP uplink port (LAN 10/100/1000)
• Supports up to 64-port un-managed 10/100 Ethernet Switch*
• Static IP or DHCP/DNS, SSL, Auto-negotiating, Half/Full Duplex, Auto
MDI/MDI-X Crossover
• TCP/IP, UDP/IP, CIP, SMTP, Built-in Web server
• Includes support for DXLink™ devices
• RJ-45 connector
CPU 404 MIPS PowerPC
• SDRAM 256 MB
• NVRAM 1 MB
• Flash 2 GB
USB Mini-AB connector (used for NetLinx Studio control)
Bidirectional RS-232
• Baud rates of 9600 (default), 19200, 38400, 57600
• DB-9 connector
USB Mini-B connector
HDMI Input and Output Boards – see page 63
DVI Input and Output Boards – see page 73
DXLink Twisted Pair Input and Output Boards – see page 79
SC Optical Input and Output Boards – see page 95
Audio Insert/Extract (expansion) Board – see page 101
Product Overview and General Specifications
21