Appendix A – DGX Configuration Software
(B) To set a standard EDID preset:
FIG. 92
Scaler Override view with Standard Presets selected
1.
Under Resolution Source, click Standard.
2.
Under Standard Presets, select the desired timing mode from the Timing Mode drop-down list.
3.
Under Standard Presets, select the resolution from the Available Display Modes drop-down list.
4.
In the device tree on the left, select an output to send the resolution information to that output.
Multiple outputs may be selected.
5.
Click Apply to transmit the selected information to the output(s). This action is temporary until
settings are stored on the connector(s) in Step 7. Otherwise, the settings last only until power is
cycled. The display re-syncs with the output(s).
6.
Verify that the display is satisfactory before proceeding.
7.
Click Save to store the currently displayed settings to the connector and persist them in memory.
(If the settings have been changed since clicking Apply, the newest settings will be saved.)
164
Device tree with Outputs
Standard selected
Standard Presets / Timing Mode options:





Instruction Manual – Enova DGX 8/16/32 Digital Media Switchers
DMT (Discrete Monitor Timing)
GTF (General Timing Formula)
CVT (Coordinated Video Timing)
CVT-RB (Coordinated Video Timing -
Reduced Blanking)
CEA (Consumer Electronics Association)
Standard 861D for HDTV