Appendix A – DGX Configuration Software
Note: If you plan to use the terminal emulation function of the software, a serial connection is
required.
To use DGX Configuration Software with the Enova DGX Switcher:
1.
Ethernet connection – Attach an RJ-45 crossover cable or a straight-through patch cable to one of
the two RJ-45 ports on the left rear of the enclosure (do not use the LAN 100/1000 port on the
right). The maximum length for the cable is 100 feet (30.5 meters).
Or
Serial connection (DB-9) – Attach a null modem serial cable without hardware flow control to the
serial Control port (DB-9 connector) on the enclosure. Use a serial cable that matches the RS-232
pin diagram in FIG. 87. Enova DGX equipment uses pins 2, 3, and 5 only.
FIG. 87
RS-232 pinout for null modem serial cable
2.
Ethernet connection – Attach the open end of the RJ-45 cable to the PC where the
DGX Configuration Software was installed.
Or
Serial connection – Attach the open end of the serial cable (DB-9) to the PC where the
DGX Configuration Software was installed.
3.
Apply power to the enclosure.
4.
On the PC, open the DGX Configuration Software.
5.
If changing the type of communication is necessary:
Ethernet connection – From the Communication menu, select Ethernet and then select Change
Settings to select the NIC Card setting.
Or
Serial connection (DB-9 only) – From the Communication menu, select Serial Port and then select
Change Settings to change the serial port and/or the baud rate for the PC's serial port. The baud rate
for the PC must match the baud rate for the enclosure. The recommended (default) baud rate setting
for serial communication with an Enova DGX Switcher is 9600.
6.
Select the desired tab in the interface (defaults to the Scaler Mode tab).
For information on the tabbed views see:





158
PC: DB-9
Scaler Mode – page 159
Scaler Override – page 161
EDID Programmer – page 166
HDCP Settings – page 172
Terminal – page 173
Enova DGX: DB-9