Appendix A – DGX Configuration Software
Note: When the following timings are in the EDID data, the Scaler Override view will not display
them: 720x400 @ 70 Hz, 720x400 @ 88 Hz, 640x480 @ 67 Hz, 832x624 @ 75 Hz, and 1152x870
@ 75 Hz. These timings can be entered in the program as custom resolutions.
Get Current Timing, Apply, and Save Buttons



File Menu Options: Open File and Save to File


Tip: When selecting outputs: select multiple, consecutive outputs by holding down the Shift key and
clicking the first and last output or select multiple, nonconsecutive outputs by holding down the
Control key and clicking on each output.
To retrieve (read) EDID timings from a destination device:
1.
From the Scaler Mode tab, select and set Manual (override) as the mode.
2.
Select the Scaler Override tab.
3.
Under EDID Source, select the Enclosure and select the Output number connected to the desired
destination from the drop-down lists. The system is queried for all compatible devices found with
the default (or last saved) communication link setting.
FIG. 90
Destination device's description, Manufacturer ID, and Product ID
4.
Click Refresh EDID. A short description of the destination device displays to the left of the drop-
down list along with the Manufacturer ID and Product ID (e.g., DELL 2408WFP; DEL; a02a).
The Scaler Override view is populated with the EDID timings from the detected device.
162
Get Current Timing button – Click to retrieve timing currently stored on the selected output.
This allows you to either apply those settings to other outputs that are connected to similar
destination devices or to save the current timing as a backup before making any
modifications.
Apply button – Click to see how well settings work. Sends currently displayed settings to the
destination. Selecting Apply does not store or persist settings. If Apply was just selected and
you close the program without saving any changes in the settings, the program asks whether
or not to save the applied settings.
Save button – Click to preserve currently displayed settings on the output connector. Sends
displayed settings to an output to store and persist them in the output's memory. This button
also persists the Scaling Override (Manual) option on the output.
Open File – Select to load the settings from a file to the program.
Save to File – Select to save the currently displayed settings to a file. The file type available
depends on the selected view.