Diagnosing Switch Problems
-> port-monitoring 6 source 2/3 inport
To configure port monitoring session 6 on port 2/3 as unidirectional and outward bound, for example,
enter:
-> port-monitoring 6 source 2/3 outport
For example, to restore port monitoring session 6 on port 2/3 to its bidirectional direction, enter:
-> port-monitoring 6 source 2/3 bidirectional

Configuring capture-type

To configure the amount of data to be captured, use the port-monitoring source capture-type command.
If the mode of capture-type is set to 'brief', only the first 64 bytes of packets will be captured. If the mode
of capture-type is set to 'full', then the full packet is captured regardless of the packet size.
For example, to configure port monitoring session 6 on port 2/3 to capture only the first 64 bytes of the
packet, enter
-> port-monitoring 6 source 2/3 capture-type brief
To configure port monitoring session 6 on port 2/3 to capture full packet, enter
-> port-monitoring 6 source 2/3 capture-type full

Displaying Port Monitoring Status and Data

A summary of the show commands used for displaying port monitoring status and port monitoring data is
given here:
show port-monitoring status
show port-monitoring file
For example, to display port monitoring data, use the
below:
-> show port-monitoring file
Destination
-------------------------------------------------------------------------------
01:80:C2:00:00:00 | 00:20:DA:8F:92:C6 |
00:20:DA:C7:2D:D6 | 08:00:20:95:F3:89 |
00:20:DA:A3:89:F6 | 08:00:20:95:F3:89 |
00:20:DA:BF:5B:76 | 08:00:20:95:F3:89 |
00:20:DA:A3:89:F6 | 08:00:20:95:F3:89 |
00:20:DA:BF:5B:76 | 08:00:20:95:F3:89 |
00:20:DA:A3:89:F6 | 08:00:20:95:F3:89 |
01:80:C2:00:00:00 | 00:20:DA:8F:92:C6 |
00:20:DA:BF:5B:76 | 08:00:20:95:F3:89 |
Note. For more information about the displays that result from these commands, see the OmniSwitch CLI
Reference Guide. The show port-monitoring command displays only 170 packets from the port monitor
file.
OmniSwitch AOS Release 7 Network Configuration Guide
Displays port monitoring status.
Displays port monitoring data.
| Source
show port-monitoring file
|
Type
| Data
BPDU
| 00:26:42:42:03:00:00:00:00:00
UDP
| 08:00:45:00:00:6B:FE:4A:40:00
UDP
| 08:00:45:00:00:6B:CF:89:40:00
UDP
| 08:00:45:00:00:6B:CF:85:40:00
UDP
| 08:00:45:00:00:6B:CF:8A:40:00
UDP
| 08:00:45:00:00:6B:CF:86:40:00
UDP
| 08:00:45:00:00:6B:CF:8B:40:00
BPDU
| 00:26:42:42:03:00:00:00:00:00
UDP
| 08:00:45:00:00:6B:CF:87:40:00
March 2011
Port Monitoring
command as shown
page 26-27

Advertisement

Table of Contents
loading

This manual is also suitable for:

Omniswitch aos 7

Table of Contents