Sampler; Poller; Configuring A Sflow Session - Alcatel-Lucent OmniSwitch AOS Release 7 Manual

Network configuration guide
Hide thumbs Also See for OmniSwitch AOS Release 7:
Table of Contents

Advertisement

Diagnosing Switch Problems

Sampler

The sampler is the module which gets hardware sampled from Q-Dispatcher and fills up the sampler part
of the UDP datagram.

Poller

The poller is the module which gets counter samples from Ethernet driver and fills up the counter part of
the UDP datagram.

Configuring a sFlow Session

To configure a sFlow receiver session, use the
by the receiver_index, name, the name of the session and address, and the IP address of the switch to be
monitored.
For example, to configure receiver session 6 on switch 10.255.11.28, enter:
-> sflow receiver 6 name sflowtrend address 10.255.11.28
In addition, you can also specify optional parameters shown in the table below. These parameters can be
entered after the IP address.
keywords
timeout
forever
udp-port
For example, to configure sFlow receiver session 6 on switch 10.255.11.28 and to specify the packet-size
and timeout value, enter:
-> sflow receiver 6 name sflowtrend address 10.255.11.28 packet-size 1400 time-
out 600
To configure a sFlow sampler session, use the
followed by the instance ID number, the slot number of the port to be monitored, a slash (/), and the port
number and receiver, the receiver_index.
For example, to configure sampler session 1 on port 2/3, enter:
-> sflow sampler 1 port 2/3 receiver 6
In addition, you can also specify optional parameters shown in the table below. These parameters can be
entered after the receiver index.
keywords
rate
sample-hdr-size
For example, to configure sFlow sampler session 1 on port 2/3 and to specify the rate and sample-hdr-size,
enter:
-> sflow sampler 1 port 2/3 receiver 6 rate 512 sample-hdr-size 128
OmniSwitch AOS Release 7 Network Configuration Guide
sflow agent
command by entering sflow receiver, followed
packet-size
version
sflow sampler
command by entering sflow sampler,
March 2011
sFlow
page 26-29