Alcatel-Lucent OmniSwitch AOS Release 7 Manual page 199

Network configuration guide
Hide thumbs Also See for OmniSwitch AOS Release 7:
Table of Contents

Advertisement

Configuring ERP
If a link or node failure occurs in the ring shown in the above illustration, the ring transitions as follows
into the protection mode:
Nodes adjacent to the failure detect and report the failure using the R-APS (SF) message.
The R-APS (SF) message triggers the RPL owner to unblock the RPL.
All nodes in the ring flush all the dynamic MAC addresses learned on their ring ports.
The ring is now operating in the protection mode, as shown below:
When the failed link shown in the above illustration recovers, the ring transitions as follows back to the
idle mode:
Nodes adjacent to the recovered link initiate an R-APS (NR) message and start the Guard Timer.
OmniSwitch AOS Release 7 Network Configuration Guide
Normal Mode
Protection Mode
March 2011
ERP Overview
page 9-5