Table 20 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YKS2x) (continued)
Message ID
YKS290E MSG SC=44
RC=44 (result)
YKS298E MSG SC=44
RC=44 (detailed-info)
Table 21 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YKT0x)
Message ID
YKT001E CON
YKT002E CON
YKT003E CON
YKT004E CON
YKT005E CON
Message Text
YKVGET program failure for:vn
YKSTORE encountered an
unexpected error.
Message Text
Can't find SVCTABLE
Can't find IGCERROR
No SVC #'s available
Couldn't add SVC entry
Couldn't create name/token
Explanation and Recommended Actions
An attempt to acquire the variable vn failed with the result
value identified by result. This error can be caused by the
YKSTORE REXX subroutine's compiled REXX module being
directly executed.
Use the YKSTORE REXX subroutine instead of directly
executing the compiled REXX module.
An unexpected error has occurred. This error might have
occurred with another error.
If another error message was output at the same time as
this one, follow the instructions in that message to fix the
corresponding problem.
If no other error message was output, collect the following
materials and contact service representative:
The script from which this command was executed (not
necessary if this command was executed from the ISPF
panel).
The ISPF log (not necessary if this command was
executed from a script).
The configuration files operated on from the script or
ISPF panel (the copy group definition file, disk
configuration definition file, command device definition
file and route list definition file).
detailed-info
Detailed information to assist service
representative in resolving the problem
Explanation and Recommended Actions
The "SVCTABLE" search in the NUCLKUP macro failed.
The program abnormally terminates with user completion
code 996.
Contact technical support for assistance.
The "IGCERROR" search in the NUCLKUP macro failed.
The program abnormally terminates with user completion
code 996.
Contact technical support for assistance.
No SVC number available. The program abnormally
terminates with user completion code 996.
SVC number addition failed in the SVCUPDTE macro.
The program abnormally terminates with user completion
code 996.
Contact technical support for assistance.
Name/Token registration failed. The program
abnormally terminates with user completion code 996.
Contact technical support for assistance.