Table 37 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YKZ21x – YKZ24x) (continued)
Message ID
YKZ228E MSG SC=36
#
RC=36
(pair-index)
YKZ229I MSG SC=0
RC=0
140 Messages
Message Text
Invalid pair attribute name = value
The time specified with ATTIME has
past. The specification of ATTIME is
ignored.
Explanation and Recommended Actions
The value of the REXX variable is invalid.
Check that the value is specified according to the
following rules:
The command control address must consist of 2
digits.
The control unit number must consist of 2 digits.
The SSID must consist of 4 digits.
The storage system serial number must consist of
5 digits.
The device number must consist of up to 4 digits.
name
REXX variable name
value
Value
pair-index
See the pair index description in
the explanation of the YKE003E
message.
#
If this message is output while the YKLOAD
command is being executed, the RC is 44.
The time assigned to the ATTIME parameter has
elapsed. Processing will continue, ignoring the
specification of the ATTIME parameter.