Table 1 1 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YKM0x) (continued)
Message ID
YKM021E ISPF
YKM022E ISPF
YKM023E ISPF
YKM024E ISPF
YKM025E ISPF
YKM026E ISPF
YKM027E ISPF
YKM030E ISPF
YKM031E ISPF
YKM032E ISPF
YKM033E ISPF
YKM034E ISPF
YKM035E ISPF
YKM036E ISPF
YKM037E ISPF
YKM038E ISPF
YKM039E ISPF
76
Messages
Message Text
Check either Device num or
Volser
The End Volser value must not
be lower than the Start Volser
Invalid value
Choose any one
C/T ID cannot be added to a
CopyGroup Container
without C/T ID.
The secondary device sdevn
is already paired to primary
device pdevn.
The primary device pdevn
and secondary device sdevn
are on different storage
systems.
File not found.
Refresh SMS key is not
available in case of Copy
Group Creation.
Invalid operation.
Can not edit.
Press F10 key and select C/T
ID.
inputfld is not specified or
invalid.
Specified APID is defined to
another DADID.
Changing a local Device
Address Domain ID is not
allowed.
Specified DEVN is not found.
Specified device is not
command device because
APID is not available.
Explanation and Recommended Actions
Select either Device Num or Volser.
The End Volser value is lower than the Start Volser value.
The value is invalid.
Choose one.
You cannot add a copy group to a copy group container if no
C/T group ID is specified for the copy group.
The secondary device indicated by sdevn is already defined as
a copy pair in the primary device indicated by pdevn.
sdevn
Secondary device number
pdevn
Primary device number
The primary device pdevn and the secondary device sdevn are
on different storage systems.
pdevn
Primary device number
sdevn
Secondary device number
The file was not found.
The Refresh SMS key is not available while a new copy group
is being created.
The operation is invalid.
This cannot be edited.
Press the F10 key, and then select a C/T group ID.
No value is specified in inputfld, or the specified value is invalid.
inputfld
The attribute name or the input field name
The APID you specified is already defined in another device
address domain ID.
Changing a local device address domain ID is not allowed.
The device number you specified was not found.
The device you specified is not a command device because the
APID cannot be used.