HP StorageWorks P9000 Manual page 127

Business continuity manager software messages
Hide thumbs Also See for StorageWorks P9000:
Table of Contents

Advertisement

Table 36 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YKZ10x – YKZ20x)
Message ID
YKZ103E MSG SC=48
YKZ201E MSG CON PRT
#
SC=44 RC=44
Message Text
Parameters combination is invalid
A GETMAIN error occurred. (return
code=nnn, size=mmm, area=area,
cmd=xxx, pos=yyy)
Explanation and Recommended Actions
The parameter combination is invalid.
The command cannot be executed because a
GETMAIN error occurred.
Expand the job execution area, and then re-execute
the command.
nnn (decimal number)
Return code from the GETMAIN macro
mmm (decimal number)
Area size
area (string)
HIGH must be equal to or greater
than 16 MB; LOW must be less than
16 MB.
xxx (decimal number)
Command code of the command
that was executing when the error
occurred
0: YKLOAD, tool, or any command
1: YKMAKE
2: YKSCAN
3: YKQUERY
4: YKRESYNC
5: YKSUSPND
6: YKDELETE
7: YKEWAIT
8: YKRECVER
9: YKSTATS
10: Remote scan function, NG scan
function
11: YKBLDPTH
12: YKDELPTH
13: YKQRYPTH
14: YKFCSTAT
16: YKFREEZE
17: YKRUN
18: YKBLDCMD
19: YKQRYDEV
20: YKDELCMD
yyy (character string)
Maintenance information
#
If this message is output when the log and trace are
obtained, the RC is 0.
List of Messages 127