Table 57 Details of Error Codes 8Dxx (continued)
Error
Error Details
Code
A copy pair cannot be made. The
8D10
reason might be one of the
following:
An inter-CU logical path has not
been set between the specified
CUs.
The storage system serial
number of the P-VOL is
incorrect.
The SSID of the P-VOL is
incorrect.
The CU number is not
supported.
The command could not be
8D11
executed because the volume
specified by the host command
parameter is in the NOT READY
status.
The command could not be
8D12
executed because the logical
volume of the specified volume by
the host command parameter is
blocked.
The command could not be
8D14
executed because the BC Z, Cnt
Ac-S Z, or TCA program product
is not installed.
A BC Z copy pair cannot be made
8D15
or resynchronized. Possible reasons
include one or more of the
following:
The status of the copy pair does
not allow the status transition.
For details, see error code
2310.
The charging limit of the
program product was
exceeded.
The copy pair is in the Pending
status.
The copy pair is not in the Split
status.
The specified C/T group ID is
not registered.
Type of Error
BC Z
Cnt Ac-S Z
Output
Not output
Not output
Output
Output
Not output
TCA
Cnt Ac-J Z
CMD
Not output
Output
Output
Not output
Details of Error Codes
PATH
Others
Output
Not
output
Not output
Not output