Table 8 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YKG2x) (continued)
Message ID
YKH201W TSO
YKH202W TSO
YKH203W TSO
YKH204W TSO
52
Messages
Message Text
No I/O paths are available
for the specified devices.
DEVN=Devn
Unable to resolve primary
volume information.
DEVN=Devn,
SN=SerialNum, CU=CU#,
CCA=CCA#
Unable to resolve secondary
volume information.
SN=SerialNum, CU=CU#,
CCA=CCA#
A dynamic configuration
change was detected.
DEVN=device-number
Explanation and Recommended Actions
No copy pair information was acquired from the volume to which
the device number Devn was assigned because no I/O paths are
available.
Verify the I/O path settings
Devn
The device number of the volume whose
information acquisition was skipped
A P-VOL not defined in the disk configuration definition file was
detected among the PPRC copy pairs detected by the YKH2B
command.
Check whether the detected P-VOL is defined in the disk
configuration definition file.
Devn
The device number of the detected undefined
volume
SerialNum
The storage system of the detected undefined
volume
CU#
The control unit number of the detected
undefined volume
CCA#
The command control address number of the
detected undefined volume
An S-VOL not defined in the disk configuration definition file was
detected among the PPRC copy pairs detected by the YKH2B
command.
Check whether the detected S-VOL is defined in the disk
configuration definition file.
SerialNum
The storage system serial number of the detected
undefined volume
CU#
The control unit number of the detected
undefined volume
CCA#
The command control address number of the
detected undefined volume
A dynamic change was detected in an I/O configuration definition
when the YKH2B command was executed either without the HS
parameter or with HS(CHECK).
Check the status of the device targeted by the YKH2B command,
correct any errors in the configuration or execution conditions (such
as the parameter setting or the times at which the command has
been executed), and then re-execute the command.
device-number
Device number being processed when a dynamic
change was detected in an I/O configuration
definition