HP StorageWorks P9000 Manual page 59

Business continuity manager software messages
Hide thumbs Also See for StorageWorks P9000:
Table of Contents

Advertisement

Table 8 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YKG2x) (continued)
Message ID
Message Text
YKJ21 1E TSO
PVOL & SVOL of Hitachi
RC=32
ShadowImage™ for
Mainframe (BC Z) pair is in
the different storage system:
dd-name: rec#
YKJ212E TSO
A specific combination of a
RC=32
storage system serial number
and a C/T group ID is used
for multiple CAJ Copy
Groups: dd-name: rec#
YKJ213E TSO
Secondary volume is already
RC=32
specified in another copy
pair as a secondary device:
dd-name: rec#
YKJ250E TSO
name is not specified in
RC=32
EXCTG information CSV file:
dd-name: rec#
Explanation and Recommended Actions
A copy pair, which has a P-VOL storage system serial number and
an S-VOL storage system serial number that do not match, was
found in a copy group of copy type BC Z.
dd-name
DD name of the CSV file where the error was
detected
rec#
Number of the line in the file identified by
dd-name where the error was detected
The combination of the copy groups is one of the following:
The serial numbers of the primary site storage systems are the same;
the serial numbers of the secondary site storage systems are
different; and copy pairs with an equal C/T group ID exist.
The serial numbers of the primary site storage systems are different;
the serial numbers of the secondary site storage systems are the
same; and copy pairs with an equal sub C/T group ID exist.
If the copy type is Cnt Ac-J Z, these combinations are not supported.
dd-name
DD name of the CSV file where the error was
detected
rec#
Number of the line in the file identified by
dd-name where the error was detected
The volume specified as the S-VOL is also specified as the S-VOL
for other copy pairs. The same volume cannot be specified as the
S-VOL for multiple copy pairs.
dd-name
DD name of the CSV file where the error was
detected
rec#
Number of the line in the file identified by
dd-name where the error was detected
No value is assigned to the item identified by name in the EXCTG
information CSV file.
name
Name of the item in the EXCTG information CSV
file
dd-name
DD name of the CSV file where the error was
detected
rec#
Number of the line in the file identified by
dd-name where the error was detected