Table 28 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YKX1x) (continued)
Message ID
YKX103E MSG SC=48
YKX104E MSG SC=48
YKX108E MSG SC=48
YKX108E MSG SC=48
YKX108E MSG SC=48
YKX108E MSG SC=48
YKX1 10E TSO RC=40
YKX166E MSG SC=48
YKX199I TSO
Table 29 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YKX2x)
Message ID
YKX200T TSO RC=48
YKX201E MSG SC=48
YKX201E MSG SC=48
YKX201E MSG SC=48
YKX201E TSO RC=48
YKX201E MSG SC=48
YKX201E MSG SC=48
106 Messages
Message Text
Parameter combination is invalid
Device# DEVN() is not found
APID() not valid hex
CCA() not valid hex
CU() not valid hex
DEVN() not valid hex
REXX failure return code=nnnn
starting with variable name
Necessary Route List is not found.
YKDELCMD command return
code=nnnn, reason code=rrrr
Message Text
Supplied parameters invalid
No command control address
CCA() supplied
No control unit# CU() supplied
No device# DEVN() supplied
No message MSG() supplied
No model SMODEL() supplied
No results STEM() supplied
Explanation and Recommended Actions
The specified parameter combination is invalid.
For details about the combination of parameters, see
the description of the YKDELCMD command in the HP
StorageWorks P9000 for Business Continuity Manager
Software Reference Guide.
The device specified in the DEVN parameter does not
exist, or a device other than DASD or a PAV ALIAS
volume has been specified.
The value specified in the APID parameter is not in
hexadecimal format.
The value specified in the CCA parameter is not in
hexadecimal format.
The value specified in the CU parameter is not in
hexadecimal format.
The value specified in the DEVN parameter is not in
hexadecimal format.
Access to the REXX variable identified by name failed.
For details about the return code, see IKJCT441 in the
TSO/E Programming Services.
nnnn
Error code returned upon REXX
access
The route list to be processed was not found.
Review the ROUTE and DAD parameters, route list
definition file, and command device definition file you
specified when executing the YKLOAD command.
The YKDELCMD command terminated with the return
code nnnn and the reason code rrrr.
Explanation and Recommended Actions
Invalid parameters are specified.
For details, see the reason code in the YKX299I
message that will appear after this message. For
reason codes, see IKJPARS in the TSO/E Programming
Services.
Nothing is assigned to the CCA parameter.
Nothing is assigned to the CU parameter.
Nothing is assigned to the DEVN parameter.
Nothing is assigned to the MSG parameter.
Nothing is assigned to the SMODEL parameter.
Nothing is assigned to the STEM parameter.

Advertisement