Table 2 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YKA0x) (continued)
Message ID
YKB001I TSO
YKB002I TSO
YKB100E TSO
YKB101E TSO
32
Messages
Message Text
YKP2B completed.
RC=return-code
No copy pair was
discovered.
Missing or invalid
parameter:
parameter-name
The specified PREFIX is
being used by another
program.
Explanation and Recommended Actions
The YKP2B command terminated.
return-code
The return code of the YKP2B command
0: The command ended successfully. The copy
group definition file was output.
4: Indicates that one of the following occurred:
The command ended successfully. No copy
pair was detected within the range of the
specified device numbers.
A copy group definition file was created, but
volume information not defined in the disk
configuration definition file for the site
specified in the DAD parameter was detected
among copy pairs within the range specified
in the DEVN parameter.
A copy group definition file was created, but
a change was detected in the I/O
configuration when the YKP2B command was
executed with CHECK specified in the HS
parameter.
8: An I/O error occurred in a volume within the
search range. The copy group definition file was
created for the volume that was successfully
detected.
44: The processing was cancelled due to an
error. The copy group definition file was not
created.
48: The command ended due to an invalid
parameter.
No copy pair was detected within the specified range. Check the
operating range and status of the copy pair that you want to
acquire, and execute the YKP2B command again. If the copy pair
status is SIMPLEX, the YKP2B command does not detect any copy
pair.
The parameter specification was invalid or missing.
Check the following, and then re-execute the command:
Make sure that the required parameter indicated by
parameter-name was specified.
Make sure that the value specified for the required parameter
indicated by parameter-name is valid.
Make sure that different device address domain (DAD) IDs for
the primary and secondary sites are specified for the DAD
parameter.
parameter-name
Name of the invalid or missing parameter
The specified prefix is being used by another program.
Check the value specified for the prefix.