HP StorageWorks P9000 Manual page 148

Business continuity manager software messages
Hide thumbs Also See for StorageWorks P9000:
Table of Contents

Advertisement

Table 38 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YKZ25x) (continued)
Message ID
YKZ253E MSG SC=32
RC=32 (pair-index)
148 Messages
Message Text
DASD device
device-number- 1 (device-number-2)
I/O error. (CC=code1 CSW=code2
code3 code4 code5, cmd=xxx,
pos=yyy).
Explanation and Recommended Actions
An I/O error occurred. Processing will continue with
this device skipped.
If a sense byte is set, the sense byte is indicated in
the YKZ255E message.
When CC=3:
The corresponding device might not be configured
or connected.
When CC=0 and CSW=xxxxxx0000xxxx (DSB=00,
CSB=00):
The corresponding device might not be configured
or connected.
When CC=0 and CSW=00000000060000:
MIH might have occurred or a logical path might not
be connected.
device-number- 1 (string)
The device that issued I/O
device-number-2 (string)
The device to be manipulated
If the device number of the device
to be operated is not found, ****
is displayed.
code1 (decimal number)
CC information
code2 (Hexadecimal number)
CSW information
code3 (Hexadecimal number)
Subcommand code
code4 (Hexadecimal number)
Completion code
code5 (Hexadecimal number)
Detailed code
xxx (decimal number)
Command code of the command
that was executing when the error
occurred
See the command code
description in the explanation of
the YKZ201E message.
yyy (string)
Maintenance information
pair-index
See the pair index description in
the explanation of the YKE003E
message.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xp p9500