HP StorageWorks P9000 Manual page 151

Business continuity manager software messages
Hide thumbs Also See for StorageWorks P9000:
Table of Contents

Advertisement

Table 38 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YKZ25x) (continued)
Message ID
YKZ257E MSG SC=32
RC=32 (pair-index)
Message Text
DASD device
device-number- 1 (device-number-2)
management error. (Message type:
code1 Reason code: code2 Error
code: code3 code4, cmd=xxx,
pos=yyy)
Explanation and Recommended Actions
Business Continuity Manager failed to complete the
requested processing. Processing will continue with
this device skipped.
Check the status of the device involving the error,
correct any errors related to the configuration or
execution conditions, and then re-execute the
command.
device-number- 1 (string)
The device that issued I/O
device-number-2 (string)
The device to be manipulated
If the device number of the device
to be operated is not found, ****
is displayed.
code1 (Hexadecimal number)
Message type
code2 (Hexadecimal number)
Reason code
code3 (Hexadecimal number)
Error code
For details about the error codes,
see
"Storage System Sense Byte
Information" (page
code4 (Hexadecimal number)
Subcommand code
xxx (decimal number)
Command code of the command
that was executing when the error
occurred
See the command code
description in the explanation of
the YKZ201E message.
yyy (string)
Maintenance information
pair-index
See the pair index description in
the explanation of the YKE003E
message.
189).
List of Messages
151

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xp p9500

Table of Contents