HP StorageWorks P9000 Manual page 172

Business continuity manager software messages
Hide thumbs Also See for StorageWorks P9000:
Table of Contents

Advertisement

Table 44 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YKZ40x) (continued)
Message ID
YKZ404E MSG SC=36
#
RC=36
YKZ405E MSG SC=36
#
RC=36
YKZ406E MSG SC=36
#1
RC=36
YKZ406E MSG SC=36
#1
RC=36
172 Messages
Message Text
Number of JNLG in the EXCTG
exceeds the limit.
Duplicate JNLG number in the Copy
Group is found. (CT ID=jj, sub CT
ID=kk)
Primary device IFType does not
support EXCTG.
Secondary device IFType does not
support EXCTG.
Explanation and Recommended Actions
The number of journal groups in the EXCTG
exceeded the maximum number allowed.
#
If this message is output while the YKLOAD
command is being executed, the RC is 44.
Duplicate journal group numbers were found in the
copy group.
In order to make the journal group pairs over multiple
storage systems correspond to copy groups which
configure a container, use different numbers in one
of the pairs of C/T group ID and sub C/T group ID
which describe the journal group number.
jj (hexadecimal number)
The journal group number specified by the C/T group
ID (00-FF)
kk (hexadecimal number)
The journal group number specified by the sub C/T
group ID (00-FF)
#
If this message is output while the YKLOAD
command is being executed, the RC is 44.
EXCTG cannot be used on a storage system that has
a P-VOL or uses the remote DKC control function.
#2
Use a device
that supports EXCTG. Also, if a scan
has not been performed after the storage system
microcode was replaced, perform another scan.
IFType
IFType value
#1
If this message is output while the YKLOAD
command is being executed, the RC is 44.
#2
EXCTG is used in a storage system where the first
two digits of the IFType are X'13' or higher.
EXCTG cannot be used on a storage system that has
a S-VOL or uses the remote DKC control function.
#2
Use a device
that supports EXCTG. Also, if a scan
has not been performed after the storage system
microcode was replaced, perform another scan.
IFType
IFType value
#1
If this message is output while the YKLOAD
command is being executed, the RC is 44.
#2
EXCTG is used in a storage system where the first
two digits of the IFType are X'13' or higher.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xp p9500

Table of Contents