Table 13 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YKM7x) (continued)
Message ID
Message Text
YKM758E ISPF
The hour, minute, or second
value is not numeric. Valid
values are 00-23 for hour,
00-59 for minute, and 00-59
for second.
YKM759E ISPF
Enter numeric characters (0-9).
YKM760E ISPF
Preset Mode cannot be used
when C/T ID is not specified.
YKM761E ISPF
Check Device Num, Volser, or
Non Gen'ed.
YKM762E ISPF
You cannot perform a NG
scan because the specified
DADID matches a local or
remote DADID.
YKM763E ISPF
You cannot perform a NG
scan because no local scan
has been performed for the
specified storage system.
YKM764E ISPF
Select one of the displayed
lines.
YKM765I ISPF
A description for the specified
error code was not found.
YKM766E ISPF
Specified Prefix is being used
by another program.
YKM767E ISPF
This command is invalid for CA
Copy Groups linkaged with
HyperSwap.
YKM768E ISPF
HS cannot be used when C/T
ID is specified.
Table 14 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YKM9x)
Message ID
Message Text
YKM901E TSO
ISPF service is not available.
YKM902E TSO
Load module is not found.
Explanation and Recommended Actions
The value for the hour, minute, or second was not numeric.
Specify a value for the hour, minute, and second in the range
00 to 23, 00 to 59, and 00 to 59, respectively.
Enter a numeric value (0-9).
You cannot set the Preset Mode without specifying a C/T group
ID.
Check the value specified in Device Num, Volser, or Non
Gen'ed.
You cannot perform a NG scan, because the specified device
address domain ID is the same as the local device address
domain ID or remote device address domain ID. For details
about the NG scan, see the HP StorageWorks P9000 for
Business Continuity Manager Software Reference Guide.
You cannot perform a NG scan, because a local scan has not
been performed for the specified storage system. For details
about the NG scan, see the HP StorageWorks P9000 for
Business Continuity Manager Software Reference Guide.
Select one of the displayed lines.
A description for the specified error code was not found.
For details about error codes, see
Information" (page
189). If the error code is not listed in the
manual, contact maintenance personnel.
The specified prefix is being used by another program.
Check the value specified for the prefix.
The command cannot be executed for BC Z copy groups with
the HyperSwap attribute.
Execute the PPRC copy pair operation from TPC-R.
If a consistency group ID is specified, you cannot specify HS
for the linkage option.
Explanation and Recommended Actions
The ISPF service is not available.
Execute the YKSTART command in an ISPF environment.
After that, you can execute whichever Business Continuity
Manager commands you need to.
The Business Continuity Manager load module was not found.
The Business Continuity Manager dataset might not be
concatenated to the LNKLST.
Revise the settings for the LNKLST, and then execute the
YKSTART command.
After that, you can execute whichever Business Continuity
Manager commands you need to.
"Storage System Sense Byte
List of Messages
83