HP StorageWorks P9000 Manual page 7

Business continuity manager software messages
Hide thumbs Also See for StorageWorks P9000:
Table of Contents

Advertisement

Table 1 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YK80x) (continued)
Message ID
Message Text
YK8008E CON
BCM Monitor initialization
failed: termination-code.
YK8009E CON
Task(task-ID) abended:
completion-code.
YK8010E CON
Module not found:
load-module-name.
YK801 1E CON
The profile is not defined in
the facility class of RACF:
xxxxxxxx.
YK8012E CON
The specified prefix is being
used by another program:
prefix-name.
YK8013E CON
BCM Monitor abended.
YK8014I CON
MODIFY command
accepted: command-name.
YK8015I CON
STOP command accepted.
YK8016E CON
Command syntax error.
Explanation and Recommended Actions
An attempt to start BCM Monitor failed because of the reason
indicated in a preceding message that was output to either the
console or dd SYSTSPRT.
Contact the center administrator. If you are the center administrator,
take action that is appropriate to the previously output message,
and then restart BCM Monitor.
termination-code (decimal number)
04: An attempt was made to start BCM Monitor without using
IKJEFT01.
20: An attempt to analyze the YKMONOPT file failed.
24: An attempt to analyze the YKMONCG file failed.
32: An error occurred while loading the process module.
36: No profile is defined in the FACILITY class of RACF.
40: The prefix specified in the YKMONCG file is being used
by the Business Continuity Manager agent.
44: An attempt to initialize the subtask failed.
The task terminated abnormally during startup of BCM Monitor.
BCM Monitor will stop.
task-ID
Name for identifying the task
completion-code
System completion code
The load module identified by load-module-name cannot be found.
BCM Monitor will stop.
Check whether the load module has been properly installed.
The STGADMIN.YKA.BCM.YKQUERY profile or the
STGADMIN.YKA.BCM.COMMANDS profile is not defined in the
FACILITY class of RACF.
Review the RACF settings, and then restart BCM Monitor.
xxxxxxxx
Maintenance information
The specified prefix prefix-name is being used by another program.
Review the YKMONCG file.
BCM Monitor terminated abnormally.
If you cannot determine the cause of this problem, obtain an ABEND
dump in SYSABEND dump format, and then make a request to
technical support to investigate the problem.
BCM Monitor accepted the MODIFY command-name command.
BCM Monitor accepted the STOP command.
There is an error in the command syntax.
Make sure that the entered command is valid.