Table 47 Details of Error Codes 20xx – 22xx (continued)
Error
Error Details
Code
The BC Z copy pair could not be
2079
made because the specified S-VOL of
BC Z copy pair is a part of a delta
resync pair.
2089
A BC Z copy pair cannot be
resynchronized (QuickRestore)
because the P-VOL of the specified
BC Z copy pair is being quick
formatted.
208A
A BC Z copy pair cannot be
resynchronized (QuickRestore)
because the S-VOL of the specified
BC Z copy pair is being quick
formatted.
2093
A BC Z copy pair cannot be
suspended if the following two
conditions exist:
The P-VOL of the specified BC Z
copy pair is the S-VOL of a TCA.
A TCA copy pair is not in the
Suspend status.
2094
When the P-VOL of the specified BC
Z copy pair is the S-VOL of a TCA,
the BC Z copy pair cannot be
suspended for one of the following
reasons:
The consistency time of the TCA
copy pair is not the latest time.
The TCA copy pair changed to
Suspend status while it was in
Pending status, and the consistency
time was disabled.
22F6
An BC Z copy pair cannot be made
because the specified P-VOL is an
S-VOL for FlashCopy.
22F7
A BC Z copy pair cannot be made
because the specified S-VOL is either
a P-VOL or S-VOL for FlashCopy.
22F9
A BC Z copy pair cannot be
resynchronized (by either
ReverseResync or QuickRestore)
because the volume is of a common
volume configuration consisting of a
P-VOL of BC Z and a P-VOL of
FlashCopy.
190 Storage System Sense Byte Information
Type of Error
BC Z
Cnt Ac-S Z
TCA
Output
Not output
Output
Not output
Output
Not output
Output
Not output
Output
Not output
Y
N
N
Y
N
N
Y
N
N
Cnt Ac-J Z
CMD
PATH
N
N
N
N
N
N
N
N
N
Others
N
N
N