HP StorageWorks P9000 Manual page 161

Business continuity manager software messages
Hide thumbs Also See for StorageWorks P9000:
Table of Contents

Advertisement

Table 42 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YKZ29x)
Message ID
YKZ290E MSG SC=48
RC=48
YKZ291I CON SC=0
RC=0
YKZ292I CON SC=0
RC=0
YKZ293E MSG CON
SC=0 RC=0
Message Text
FROMCU() exceeds number of CU
that storage systems supported.
The log dataset is full. (DSN=ddd,
cp=xxx:yyy)
The log dataset was switched.
(from=YKLOGmm, to=YKLOGnn,
job=jjj, cp=xxx:yyy)
The specified value for the system
symbol &YKLOGPT is invalid.
Explanation and Recommended Actions
The FROMCU has exceeded the maximum number of
CUs that are supported by storage systems.
Specify the maximum supported number of CUs or
less.
The log dataset is full.
ddd
Name of the log dataset that
became full
If a log dataset name cannot be
collected, * is displayed.
xxx (decimal number)
Command code for the command
that was executing when the log
dataset became full
See the description for the
command code in the YKZ201E
message.
yyy (string)
Maintenance information
The log dataset was switched.
YKLOGmm
Previous log dataset (YKLOG01 or YKLOG02)
YKLOGnn
New log dataset (YKLOG01 or YKLOG02)
jjj
Job name
xxx (decimal number)
Command code for the command
that was executing when the log
dataset was switched
See the description for the
command code in the YKZ201E
message.
yyy (string)
Maintenance information
The value specified for the &YKLOGPT system symbol
is invalid. The program continues processing while
assuming LOGR.
Revise the value specified for the &YKLOGPT system
symbol.
List of Messages