HP StorageWorks P9000 Manual page 159

Business continuity manager software messages
Hide thumbs Also See for StorageWorks P9000:
Table of Contents

Advertisement

Table 41 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YKZ28x) (continued)
Message ID
YKZ281E MSG SC=36
#1
RC=36
(Storage
System's-IFType)
YKZ282E MSG SC=36
#1
RC=36
YKZ282E MSG SC=36
#1
RC=36
YKZ283T MSG SC=36
#
RC=36
Message Text
Some of the storage systems do not
support Remote Control.
Primary device IFType does not
support CAJ.
Secondary device IFType does not
support CAJ.
subCTGroupID value null or invalid.
Explanation and Recommended Actions
The device specified during command device usage
does not support the remote DKC control function.
Check whether the device can use the remote DKC
#2
control function
, and then revise the remote DKC
control function definitions.
Storage System's-IFType
IFType value of the storage
system
#1
If this message is output while the YKLOAD
command is being executed, the RC is 44.
#2
The remote DKC control function can be used in
a storage system on the Lightning storage system
models (or later) where the first two digits of the
IFType are X'04' or higher.
Cnt Ac-J Z cannot be used on a storage system that
has a P-VOL or uses the remote DKC control function.
#2
Use a device
that supports Cnt Ac-J Z. Also, if a
scan was not performed after the storage system
microcode was replaced, perform another scan.
IFType
IFType value
#1
If this message is output while the YKLOAD
command is being executed, the RC is 44.
#2
The Cnt Ac-J Z is used in a storage system where
the first two digits of the IFType are X'11' or higher.
Cnt Ac-J Z cannot be used on a storage system that
has an S-VOL or uses the remote DKC control
function.
#2
Use a device
that supports Cnt Ac-J Z. Also, if a
scan was not performed after the storage system
microcode was replaced, perform another scan.
IFType
IFType value
#1
If this message is output while the YKLOAD
command is being executed, the RC is 44.
#2
The Cnt Ac-J Z is used in a storage system where
the first two digits of the IFType are X'11' or higher.
subCTGroupID in the copy group structure is either
NULL or invalid.
Correct the configuration file, and then execute the
YKLOAD command.
value
REXX variable value
#
If this message is output while the YKLOAD
command is being executed, the RC is 44.
List of Messages 159