Table 40 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YKZ27x) (continued)
Message ID
YKZ276E MSG SC=36
RC=36
YKZ277W MSG SC=4
RC=4
YKZ278W MSG SC=8
RC=8
YKZ279W MSG SC=12
RC=12
Table 41 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YKZ28x)
Message ID
YKZ280W MSG SC=0
RC=0
YKZ280W MSG SC=0
RC=0
158 Messages
Message Text
Some of the arrays do not support
storage system type paths.
Some paths are in the NOPATH
state.
Some paths are in the MISMATCH
state.
Some paths are in the INVALID state.
Message Text
Primary volume's IFType is larger
than Remote control's IFType value.
Secondary volume's IFType is larger
than Remote control's IFType value.
Explanation and Recommended Actions
A storage system using a path-controlled device or
Remote Disk Controller control contains an IFType,
which is not supported for disc controller-type path
control.
In the configuration file, make sure that the storage
system is controllable (that the first two digits of the
IFType are X'11' or higher). Also, if scanning was
not performed after the storage system microcode
was replaced, perform another scan.
There is a logical path without a physical path
established.
Logical paths were detected for which the port
information stored in the REXX variable did not match
the port information set on the storage system. The
port number or number of ports that have been set
is incorrect.
Logical paths containing physical paths in the
INVALID status were detected from a storage system.
Explanation and Recommended Actions
The IFType of a storage system using the Remote
DKC Control Function is smaller than the IFType of
the P-VOL defined in the copy group. As such, the
smaller of the two will be used when each command
is executed. Note that on some machine types, some
functionality might be lost. Also, if a scan was not
performed after the storage system microcode was
replaced, perform another scan.
value
IFType value of the remote
storage system
The IFType of a storage system using the Remote
DKC Control Function is smaller than the IFType of
the S-VOL defined in the copy group. As such, the
smaller of the two will be used when each command
is executed. Note that on some machine types, some
functionality might be lost. Also, if a scan was not
performed after the storage system microcode was
replaced, perform another scan.
value
IFType value of the remote
storage system