Table 38 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YKZ25x) (continued)
Message ID
YKZ254E MSG SC=8
RC=8
Message Text
DASD device
device-number- 1 (device-number-2)
I/O error. (CC=code1 CSW=code2
code3 code4 code5, cmd=xxx,
pos=yyy).
Explanation and Recommended Actions
An I/O error occurred. Business Continuity Manager
might not support this device. Processing will continue
with this device skipped.
If a sense byte is set, the sense byte is indicated in
the YKZ256E message.
When CC=3:
The corresponding device might not be configured
or connected.
When CC=0 and CSW=xxxxxx0000xxxx (DSB=00,
CSB=00):
The corresponding device might not be configured
or connected.
When CC=0 and CSW=00000000060000:
MIH might have occurred or a logical path might not
be connected.
device-number- 1 (string)
The device that issued I/O
device-number-2 (string)
The device to be manipulated
code1 (decimal number)
CC information
code2 (Hexadecimal number)
CSW Information.
code3 (Hexadecimal number)
Subcommand code
code4 (Hexadecimal number)
Completion code
code5 (Hexadecimal number)
Detailed code
xxx (decimal number)
Command code of the command
that was executing when the error
occurred
See the command code
description in the explanation of
the YKZ201E message.
yyy (string)
Maintenance information
List of Messages 149