HP StorageWorks P9000 Manual page 147

Business continuity manager software messages
Hide thumbs Also See for StorageWorks P9000:
Table of Contents

Advertisement

Table 38 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YKZ25x) (continued)
Message ID
YKZ252E MSG SC=8
RC=8
Message Text
DASD device
device-number- 1 (device-number-2)
management error, message-text.
(code1 code2, cmd=xxx, pos=yyy)
Explanation and Recommended Actions
Business Continuity Manager failed to complete the
requested processing.
This device is skipped and processing continues.
Check the status of the error device, and fix the
problem in the configuration or execution condition
if any.
device-number- 1 (string)
The device that issued I/O
device-number-2 (string)
The device to be manipulated
message-text (string)
Message text
code1 (Hexadecimal number)
Subcommand code
code2 (Hexadecimal number)
Error code
For details about the error codes,
see
"Storage System Sense Byte
Information" (page
xxx (decimal number)
Command code of the command
that was executing when the error
occurred
See the command code
description in the explanation of
the YKZ201E message.
yyy (string)
Maintenance information
189).
List of Messages