HP StorageWorks P9000 Manual page 139

Business continuity manager software messages
Hide thumbs Also See for StorageWorks P9000:
Table of Contents

Advertisement

Table 37 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YKZ21x – YKZ24x) (continued)
Message ID
YKZ224E MSG SC=12
#
RC=36
(pair-index)
YKZ225E MSG SC=36
#
RC=36
YKZ226E MSG SC=36
#
RC=48
YKZ227E MSG SC=36
#
RC=36
Message Text
Secondary device does not support
TCA
Some pairs in this group do not
support BC Z or CA Group ID
membership.
stemTCA_MAP=TRK not supported
by some group pairs
stemTCA_FLOWCONTROL=N not
supported by some group pairs.
Explanation and Recommended Actions
TCA cannot be used on a storage system with an
S-VOL.
Use a device that supports TCA.
pair-index
See the pair index description in
the explanation of the YKE003E
message.
#
If this message is output while the YKLOAD
command is being executed, the RC is 44.
This group contains copy pairs that do not support
BC Z or Cnt Ac-S Z Group ID.
Correct the configuration file, and then re-execute
the YKLOAD command.
#
If this message is output while the YKLOAD
command is being executed, the RC is 44.
For the specified model, TRK cannot be specified for
TCA_MAP in the TCA options.
Correct the contents of the configuration file.
stem
Stem name
#
If this message is output while the YKLOAD
command is being executed, the RC is 44.
Some copy pairs in this group do not support
TCA_FLOWCONTROL=N.
Correct the configuration file, and then re-execute
the YKLOAD command.
stem
Stem name
#
If this message is output while the YKLOAD
command is being executed, the RC is 44.
List of Messages 139

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xp p9500

Table of Contents