Table 37 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YKZ21x – YKZ24x) (continued)
Message ID
#
YKZ212W CON
RC=0
YKZ215W MSG CON
SC=0 RC=0
Message Text
A FREEMAIN error occurred. (return
code=nnn, cmd=xxx, pos=yyy)
A GTRACE error occurred. (return
code=nnn, id=mmm, length=lll,
cmd=xxx, pos=yyy)
Explanation and Recommended Actions
A FREEMAIN error occurred.
nnn (decimal number)
Return code of the FREEMAIN
macro
xxx (decimal number)
Command code of the command
that was executing when the error
occurred
See the command code
description in the explanation of
the YKZ201E message.
yyy (string)
Maintenance information
#
If this message is output at a time other than when
the log and trace are obtained, the YKZ212W
message is not output to the console, but is recorded
in LOG and TRACE. Processing will then continue.
A GTRACE macro error occurred.
If this message appears frequently, stop acquiring
GTF traces for the USR trace (TRACE=USR). If the
cause of the error is insufficient capacity in the trace
buffer or trace data set, increase the capacity, and
then restart GTF.
nnn (decimal number)
Return code of the GTRACE macro
mmm (decimal number)
Event ID
lll (decimal number)
Length of trace data
xxx (decimal number)
Command code of the command
that was executing when the error
occurred
See the command code
description in the explanation of
the YKZ201E message.
yyy (string)
Maintenance information