Table 1 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YK80x) (continued)
Message ID
Message Text
YK8028E CON
BCM Monitor function
abend: code=Sxxx Uxxxx
abended-module=module-name
C-Date=module-creation-date
base=bbbbbbbb disp=dddd
[calling-module=module-name
C-Date=y'y'.m'm'.d'd'
base=bbbbbbbb
disp=dddd]
PSW=pppppppp pppppppp
ILC=ll INTC=xx
Registers at time of failure
GR 00-03
contents-of-register-0
contents-of-register- 1
contents-of-register-2
contents-of-register-3
GR 04-07
contents-of-register-4
contents-of-register-5
contents-of-register-6
contents-of-register-7
GR 08- 1 1
contents-of-register-8
contents-of-register-9
contents-of-register- 1 0
contents-of-register- 1 1
GR 12- 1 5
contents-of-register- 1 2
contents-of-register- 1 3
contents-of-register- 1 4
contents-of-register- 1 5
YK8031W CON
The specified error-type is
invalid: command-name.
Explanation and Recommended Actions
The main task or subtask terminated abnormally during BCM
Monitor processing. If the task cannot be recovered, BCM Monitor
will stop.
Contact the center administrator.
Sxxx (hexadecimal number)
System completion code when the task
terminated abnormally
Uxxxx (decimal number)
User completion code when the task terminated
abnormally
module-name
Section name of the BCM Monitor module or
load module name.
If the module cannot be identified, UNKNOWN is
displayed. In this case, the values of
y'y'.m'm'.d'd' and bbbbbbbb are invalid.
module-creation-date
This is displayed in one of the following formats:
y'y'.m'm'.d'd': Creation date of the module identified by
module-name
y'y'/m'm'/d'd': Creation date of the module identified by
module-name
bbbbbbbb
Contents of the base register
dddd
ABENDED-MODULE: Location where ABENDED-MODULE was
called, relative to the top of the module
CALLING-MODULE: Location where CALLING-MODULE was
called, relative to the top of the module
pppppppp pppppppp
PSW during the abnormal termination
ll
Length of the command during the abnormal
termination
xx
Interrupt code during the abnormal termination
The value identified by error-type, which was specified in the
command-name command, is invalid.
error-type
label: The label name is invalid. Check the label name for
ACTION=STOPPOINT specified in the YKMONCG file.
copy group: The copy group ID is invalid. Check the copy
group ID for CGID specified in the YKMONCG file.
List of Messages