Chapter 56
Configuring Fibre Channel Write Acceleration
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
Figure 56-2
Select the initiator and target WWNs and VSAN IDs and check the WriteAcc check box to enable Fibre
Step 3
Channel write acceleration on this SCSI flow.
Optionally, enable SCSI flow statistics on this SCSI flow at this time by checking the Enable Statistics
Step 4
check box.
Optionally, set the BufCount value to the number of 2K buffers used by the SCSI target.
Step 5
Click Create to create this SCSI flow with Fibre Channel write acceleration.
Step 6
Default Settings
Table 56-1
Table 56-1
Parameters
Fibre Channel write acceleration
Fibre Channel write acceleration buffers
OL-16184-01, Cisco MDS SAN-OS Release 3.x
FC Write Acceleration Dialog Box
lists the default settings for Fibre Channel write acceleration parameters.
Default Fibre Channel Write Acceleration Parameters
Default
Disabled.
1024.
Cisco MDS 9000 Family CLI Configuration Guide
Default Settings