Enabling Rmon Alarms For Physical Components - HP Cisco MDS 9216 - Fabric Switch Configuration Manual

Cisco mds 9000 family fabric manager configuration guide, release 3.x (ol-8222-10, april 2008)
Hide thumbs Also See for Cisco MDS 9216 - Fabric Switch:
Table of Contents

Advertisement

Configuring RMON Using Threshold Manager
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m

Enabling RMON Alarms for Physical Components

To configure an RMON alarm for a physical component using Device Manager, follow these steps:
Choose Admin > Events > Threshold Manager and click the Physical tab.
Step 1
You see the Threshold Manager dialog box with the Physical tab selected (see
Figure 61-4
Step 2
Check the check box in the Select column for each variable to monitor.
Step 3
Enter the threshold value in the Value column.
Step 4
Enter the sampling period in seconds.
Step 5
Choose one of the following severity levels to assign to the alarm: Fatal(1), Warning(2), Critical(3),
Error(4), Information(5).
Step 6
Click Create.
Step 7
Confirm the operation to define an alarm and a log event when the system prompts you to define a
severity event.
If you do not confirm the operation, the system only defines a log event.
Step 8
Click More, then click the Alarms tab in the Threshold Manager dialog box to verify the alarm you
created (see
Figure 61-5
Step 9
Close both dialog boxes.
Cisco MDS 9000 Family CLI Configuration Guide