Configuring RMON Using Threshold Manager
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m

Enabling RMON Alarms for VSANs

To enable an RMON alarm for one or more VSANs using Device Manager, follow these steps:
Choose Admin > Events > Threshold Manager and click the Services tab.
Step 1
You see the Threshold Manager dialog box.
Step 2
Click the Services tab.
You see the Threshold Manager dialog box with the Services tab selected (see
Figure 61-2
Step 3
Enter one or more VSANs (multiple VSANs separated by commas) to monitor in the VSAN ID(s) field.
Use the down arrow to see a list of available VSANs to choose from.
Step 4
Check the check box in the Select column for each variable to monitor.
Step 5
Enter the threshold value in the Value column.
Step 6
Enter the sampling period in seconds.
Choose a severity level to assign to the alarm (Fatal, Critical, Error, Warning, or Information).
Step 7
Click Create.
Step 8
Confirm the operation to define an alarm and a log event when the system prompts you to define a
Step 9
severity event.
If you do not confirm the operation, the system only defines a log event.
Click More, then click the Alarms tab in the Threshold Manager dialog box to verify the alarm you